TELEPHONES PROGRAMMING
P
rogramming the telephones.
In case of a general entrance door panel, program the telephones only from each internal
building door panel, as described on the corresponding instruction manual.
If this door panel is installed on an internal building of a residential complex or on a single
building, program the telephones as follows:
golmar
13:15
Switch off the telephone to be programmed.
Once the telephone is off, press the door release push button.
With the door release push button pressed
switch on the telephone.
To show that the system is ready for programming, the panel
will reproduce a sound and the LCD will display the
message
release push button can be released. Lift the handset
to stablish audio communication with the door panel.
1
0
O.K.
Each apartment must have one master unit only; in case of parallel units configure them
as slaves, both monitors or telephones.
Repeat these steps to program the rest of telephones.
Once the programming has been finished exit from the programming menu by pressing
CANCEL key. If you don't, the door panel will automatically exit after 90 seconds
with no operation.
To enter the door panel into program mode, press
key symbol and enter the installer PIN code
(factory default: 1315), as described on page 106.
program mode
. At this moment, the door
Enter the code that will be used to call to
this telephone and press the bell key.
At this moment the panel will reproduce
a sound and the telephone led will blink.
To program the telephone as master,
switch it off and on again.
To program it as slave, press the door
release push button.
To program it as slave with intercom
function press the center push button.
126
127
C
onnexion of an a.c. lock release.
As it is described on page 117, the lock releases to be connected to the door panel
must be d.c. type. If an a.c. lock release has been installed before, use a R-3
relay unit and a TF-104 transformer, and connect them to the lock release
as it is shown on the enclosed diagram.
TF-104
SEC
~
~
L
ink of several power supplies units.
If the quantity of monitors or telephones to be connected is bigger than the supported
from one power supply (see page 117), use additional power supplies to match the
required quantity. The first power supply should be connected to the door panel and
to the first group of monitors or telephones; connect the next groups to the positive
terminal of its corresponding power supply.
To wire several power supplies link their ground terminals;
NEVER link positive terminals of different power supplies.
1st FA-Plus
PRI
SEC
~
~
+ +
Main
INSTALLATION DIAGRAMS
Door panel
R-3
1
2
3
C
4
5
6 0
7
8
9
CN1
O
B
R
T
M
CV-
CV+
-
+
D
A
A
out
in
2nd FA-Plus/C or FA-Plus
PRI
SEC
-
-
~
~
+ +
-
-
Main
V
V
V
V
Malla
in-
in+
out+
out-
To the second group of
monitors or telephones.
To the door panel and to
the first group of monitors
or telephones.