Operation
Reading of error code E9
If E9 is read out, at least one error was made with
respect to the sequence of operations when performing
optimisation (System messages
— Abort the optimisation program by pressing
the STOP key and, if desired, start optimisation
once again.
Fig. 7-41 OPTIMISATION "12"
(4th measuring run of tyre/rim assembly)
Clamp the wheel on the balancer.
Rotate the wheel such that the valve is exactly
perpendicular to and above the main shaft.
Confi rm the valve position by pressing key 8.
The OPTIMISATION "13" screen (Fig. 7-42) is
displayed.
Fig. 7-42 OPTIMISATION "13"
START is displayed on the screen.
Spinn the wheel.
A measuring run is performed.
The BALANCING screen (Fig. 7-43) is displayed.
Finish weight Optimisation
Fig. 7-43 BALANCING
— Balance the wheel according to the readings.
Fig. 7-44
If the wheel running conditions are optimal, the
following codes can be displayed:
H0 Wheel running conditions cannot be improved by
optimisation.
H1 Further optimisation not recommended but
feasible.
H2 Weight minimisation is recommended, optimisation
can achieve no further improvement.