Anexo D
D.1 Mensajes de error del SCALANCE X300 / X400
Avisos cuando se produce un error
Observer stopped recovering because of too many
(<número de errores>) repeated errors.
(Observer needs to be restarted (WBM/CLI) ma‐
nually).
Power down on line <ID de la fuente de alimenta‐
ción>.
Internal error: <tensión> V power down.
Wrong module <nombre de módulo> on slot <nú‐
mero de slot> (ID: <ID de módulo>).
C-PLUG not accepted. See System C-PLUG mask for
details.
C-PLUG interface unmounted. Restart required.
C-PLUG missing.
Media module for ring <número de puerto> mis‐
sing.
DIP switch <nombre del interruptor> changed. Res‐
tart required.
DIP switch <nombre del interruptor> differs from C-
PLUG. Restart required.
Internal error(s) and/or exception(s) occurred.
Device boot up incomplete.
RM <dirección MAC> lost.
Media module for standby <número de puerto>
missing.
PNIO fault - please use STEP 7 for diagnostics.
PNIO connection established.
Severe module change detected. Restart required. Severe module change reverted.
DIP switch settings manipulated ...
→ Redundancy will be started after next restart.
Authentication status on <número de puerto>: FAI‐
LED! Reason: %s.
Standby <observer | partner> freezes current state
<active | passive> because <master | slave> <direc‐
ción MAC> gone.
Default route is stored in hardware.
Non-recoverable error on ring %u: RM receives test
frames from only one ring port.
Non-recoverable error on ring %u: Another redun‐
dancy manager detected.
Last MRP manager in ring %d won't stop on ring
ports <número de puerto> and <número de puer‐
to> (danger of network loops).
Redundancy mode transition not completed !\nis:
\"%s\", should: \"%s\".
Erroneous connected ring line on <número de
puerto> (should <número de puerto>).
404
Avisos tras solucionar un error
Observer restarted because of user command.
Power up on line <ID de la fuente de alimentación>.
Internal error gone: <tensión> V power is back.
Wrong module <nombre de módulo> on slot <nú‐
mero de slot> removed.
C-PLUG accepted.
C-PLUG interface mounted.
C-PLUG detected.
Media module for ring <número de puerto> detec‐
ted.
DIP switch <nombre del interruptor> set back to
original state.
DIP switch <nombre del interruptor> set back to
state saved on C-PLUG.
Internal error(s) and/or exception(s) confirmed.
Device boot up complete.
RM <dirección MAC> detected.
Media module for standby <número de puerto>
detected.
PNIO fault - gone.
PNIO connection terminated.
DIP switch settings reset ...
→ Redundancy mode will not change after next
restart.
Authentication status on <número de puerto>: OK.
Reason: %s.
Unfreeze standby state <active | passive> because
partner <dirección MAC> became visible.
Default route no longer in hardware.
Non-recoverable error gone on ring %u: RM recei‐
ves test frames from both ring ports.
Non-recoverable error gone on ring %u: Other re‐
dundancy manager gone.
MRP ring %d manager may stop now (no danger of
network loops anymore).
Redundancy mode transition to \"%s\" completed.
Erroneous connected ring line removed on <núme‐
ro de puerto>.