7.4
Registro 0x802A (PDPortDataReal)
Estructura
typdef struct{
Word BlockType;
Word BlockLength;
Byte BlockVersionHigh;
Byte BlockVersionLow;
Word Padding;
Word SlotNumber;
Word SubslotNumber;
Byte LengthOwnPortID;
8 Byte OwnPortID;
Byte NumberOfPeers;
Word Padding;
Byte LengthPeerPortID;
8 Byte PeerPortID;
Byte LengthPeerChassisID;
8 Byte PeerChassisID;
Word Padding;
DWord LineDelay;
6 Byte PeerMACAddress;
Word Padding;
Word MAUType;
Word Padding;
DWord DomainBoundary;
DWord MulticastBoundary;
Word LinkState;
Word Padding;
DWord MediaType;};
BlockType
Constante = 0x020F
BlockLength
Constante, designa la longitud del registro sin los campos BlockType y BlockLength.
BlockVersionHigh
Constante = 1, designa la Major Version.
BlockVersionLow
Constante = 0, designa la Minor Version.
SCALANCE X-300/X408-2 V4.1.7 / SCALANCE X414-3E V3.10.2
Manual de configuración, 05/2023, C79000-G8978-C187-34
Funciones PROFINET IO
7.4 Registro 0x802A (PDPortDataReal)
365

Publicidad