Activation time of the courtesy light contact. Value expressed in seconds. At the beginning of
tls
each manoeuvre the contact latches for the set time.
See the description of AUX1 parameter.
It selects the flashing mode of the barrier lights (output 24Vdc AUX2 or N.O. contact of the output
AUX 1 configured with logic 2) .
ROD CLOSED
lBAR
0
1sec. ON / 1se.c OFF
1
OFF
2
ON
3
ON
Selects the functioning mode of the auxiliary output 1 (N.O. clean contact)
0: Open barrier light, close contact when the barrier is open, open contact when the barrier is
close, intermittent during the maneuver (fig. 15, SCA)
1: Second radio cannel of the built in receiver
2: Boom light, for controlling the LED light installed on the BOOM (EVA5.A), see also the pa-
rameter LBAR.
aux1
3: Courtesy light, the contact remains close according to the parameter TLS (fig.15 SERVICE
LIGHT)
4: Photocells test, see wiring diagram in Fig.15 (PHOTOTEST)
5: Close contact with open barrier
6: Close contact with close barrier
7: Maintenance warning light. The contact closes when the number of manoeuvres set in the
Maintenance Cycle menu is reached (MACI).
Selects the functioning mode of the auxiliary output 1 (24Vdc 800 mA max.)
0: Open barrier light, close contact when the barrier is open, open contact when the barrier is
close, intermittent during the maneuver (fig. 15, SCA)
1: Second radio cannel of the built in receiver
2: Boom light, for controlling the LED light installed on the BOOM (EVA5.A), see also the pa-
rameter LBAR.
aux2
3: Courtesy light, the contact remains close according to the parameter TLS (fig.15 SERVICE
LIGHT)
4: Photocells test, see wiring diagram in Fig.15 (PHOTOTEST)
5: Close contact with open barrier
6: Close contact with close barrier
7: Maintenance warning light. The contact closes when the number of manoeuvres set in the
Maintenance Cycle menu is reached (MACI).
* ATTENTION: A WRONG SETTING OF THESE PARAMETERS CAN BE DANGEROUS.
RESPECT THE REGULATION IN FORCE!
MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or transmitter impulse has no
IbL
effect during the opening phase.
Off: condominium function disabled.
The multi-flat function is enabled or disabled during the TCA counting.
On: the bloc of flat function is enabled. The Step-by-Step signal or the transmitter signal has no
ibca
effect during the TCA counting.
Off: the bloc of flat function is disabled.
Enables or disables rapid closing
On: rapid closure is enabled. With open bar, or in the opening phase, the activation of the pho-
SCL
tocell causes the automatic closure 3sec after the total opening of the gate. It is activated only
with TCA:ON
Off: rapid closing disabled.
Selects the operating mode of the "Step by step button" and of the transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
PRE
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
Enabled or disables HOLD-TO-RUN function
On: HOLD-TO-RUN function.
htr
The pressure of the OPENS/CLOSES button must be maintained throughout the entire manoeuvre.
The opening of the STOP input stops the motor. All the safety inputs are deactivated.
Off: Automatic/semiautomatic function
Selects the operating mode of the blinking light during the time TCA
ltca
On: Blinking light on during TCA
Off: Blinking light off during TCA
28
ROD IN OPENING PHASE
ROD OPEN
0,5sec. ON / 0,5sec. OFF
1 sec. ON / 1 sec. OFF
ON
0,5sec. ON / 0,5sec OFF
1 sec. ON / 1 sec. OFF
0,5sec. ON / 0,5sec. OFF
14.3.3) LOGICS (LOG)
FUNCTION
ROD IN CLOSING PHASE
0,5 sec. ON / 0,5 sec. OFF
ON
ON
0,5 sec. ON / 0,5 sec. OFF
ON
0,5 sec. ON / 0,5 sec. OFF
1-240 (60)
0-3-(0)
0-6-(0)
0-6-(2)
ON-OFF-(Default)
MEMO
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)