Removing the telescopic guides. Fig. 16
(Take the left side as an example to remove the guides on the right side).
1. Lift up one end of the telescopic guides with force.
2. Lift all telescopic guides and remove them by pulling them backwards.
Replacing the power cable. Fig. 17
Important
The replacement of the mains cable must only be carried out by the official Cecotec Technical
Support Service or by a qualified and authorised electrician.
Position A shows the position of the junction box at the rear of the oven.
a.
Turn off the power; use a small screwdriver to remove screws 1 and 2.
Use a Phillips screwdriver to unscrew screws 3, 4, 5 and 6.
b.
Fit the new power cable: place the yellow/green cable in connector 3, the brown cable in
c.
connector 4 and the blue cable in connector 5.
When screw 6 is turned, the junction box cover closes, and the replacement is complete.
d.
Fig. 17 key
7.- Brown wire (phase L)
8.- Yellow-Green wire (ground)
9.- Blue wire (neutral N)
6. TROUBLESHOOTING
If there is a fault, before contacting Cecotec Technical Support Service, make sure it is not
-
caused by an improper use and check the following table to try and solve the problem on
your own. In most cases, the user itself can solve technical faults easily.
If you do not get the desired results with certain foods, you can find many tips and
-
preparation instructions at the end of the instruction manual.
Problem
The appliance does
not work
BOLERO HEXA SM406000 EDGE+ A+ / BOLERO HEXA SM406000 GLASS BLACK A+ / WHITE A+ / GREY A+
Blown fuse
Power cut.
Possible cause and solution
Check the control and protection elements of the
electrical panel in your home
Check if the kitchen light or any other appliances
work.
ENGLISH
81