Descargar Imprimir esta página

NORAUTO JL-VWB6L Manual De Usuario página 71

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
Ambient temperature range
Humidity
Installation altitude
NOISE
Noise values measured according to EN ISO 2151:2008. (K = 3)
Acoustic pressure level L
Acoustic power level L
ATTENTION! The sound power level may exceed 85 dB(A), in this case
individual hearing protection shall be worn.
PERFORMANCE TESTING
Frequency of performance testing and inspection:
1.
Daily
Safety valve
Drain valve
2.
Weekly
Pressure tank
3.
Monthly
Intake filter
REGULAR CLEANING, MAINTENANCE
WARNING! Before performing any inspection, maintenance, cleaning
procedures or leaving it unattended, make sure that:
- the ON/OFF power switch (7) of the air compressor is in its "OFF" position,
- the unit is unplugged from the electrical outlet,
- the air is drained from the tank
After finishing work with the tool, press the ON/OFF switch to switch off the
compressor and disconnect the compressor from the power supply.
Water, oil and dirt must not get inside the tool.
The safety valve should be checked daily for damage and inspected as mentioned
in the above table.
+5 °C - +40 °C
> 50 % (max. temperature: +40 ºC)
< 1000 m
pA
wA
Check the safety
The safety valve is set to the maximum
valve for correct
allowable pressure of the pressure tank.
operation by
It is not permitted to adjust the safety
turning it.
valve or remove its seal.
Check for any
It is necessary to clean this drain valve
visible problem.
and remove dust and dirt.
Check for any
A pressure tank may not be operated
visible problem.
if it has defects that pose a risk to
employees or third persons.
The pressure tank should be regularly
checked for damage, such as rust.
If you discover damage, please contact
the customer service centre.
This filter should
The filter can be appropriately removed.
be cleaned
at least every
100 operating
hours.
79 dB(A)
92 dB(A)
EN
69

Publicidad

loading

Este manual también es adecuado para:

98685