Please note.
The safety distance between the sides of the hob and the interior surfaces of the counter must
be at least 3 mm.
Fig. 3
L (mm)
W (mm)
590
520
In any case, make sure the induction hob is well ventilated and the air inlet and outlet are not
blocked. Make sure the induction hob works correctly. Fig. 4
Please note.
The safety distance between the hob and a cabinet over the hob must be at least 760 mm. Fig.
5
A (mm)
B (mm)
760
Min. 50
Proper ventilation
To avoid accidental contact with the bottom of the hob while it is hot, or receiving an unexpected
electric shock during use, it is necessary to place a wooden insert, fixed with screws, at a
minimum distance of 50 mm from the bottom of the hob. Follow the indications on Figure 6.
Warning
-
There are ventilation gaps around the exterior of the hob. You must ensure these gaps are
not blocked by the counter when placing the hob.
-
Please note that the glue that binds the plastic or wooden material to the furniture must
withstand a temperature of more than 150℃ to prevent the coating from peeling off.
-
The rear wall and the adjacent and surrounding surfaces must be able to withstand a
temperature of 90ºC.
Before installing the hob
-
Make sure the counter in which you install the hob is levelled, complies with the space
requirements, and is made of a heat-resistant and insulated material.
-
If you install the cooking hob over an oven, the latter must have a cooling fan.
-
The installation must comply with all the safety requirements and the applicable rules and
regulations.
-
The hob incorporates a safety switch that allows it to be completely disconnected from
the mains, which has been installed and positioned in accordance with local electrical
rules and regulations.
H (mm)
D (mm)
62
58
C (mm)
D
Min. 20
Air inlet
A (mm)
B (mm)
560 +4
490 +4
+1
+1
E
Air outlet 5 mm
ENGLISH
X (mm)
F (mm)
50 min.
3 min.
BOLERO SQUAD I 3001