Danger
Risk of injury! Follow the respective safety
regulations when operating at gas stations
or other dangerous areas.
Please do not let mineral oil contaminated
waste water reach soil, water or the sew-
age system. Perform engine cleaning and
bottom cleaning therefore only on speci-
fied places with an oil trap.
Safety Devices
Safety devices serve for the protection of
the user and must not be put out of opera-
tion or bypassed with respect to their func-
tion.
Overflow valve
If the hand spray gun is closed, the over-
flow valve opens and the high pressure
pump diverts the water back to the pump
suction side. Thus the permissible working
pressure is not exceeded.
The overflow valve is set by the manufac-
turer and sealed. Setting only by customer
service.
Start up
Danger
Risk of injury! Device, tubes, high pressure
hose and connections must be in faultless
condition. Otherwise, the appliance must
not be used.
Check oil level of the high pressure
pump
Check oil level of the high pressure
pump at the oil sight glass.
Do not operate the appliance if the oil
level has fallen below "MIN".
Add oil if required (see technical speci-
fications).
All manuals and user guides at all-guides.com
EN
Motor
Follow the instructions given in the sec-
tion "Safety Notes"!
Read the operating instructions of the
engine manufacturer before start-up
and follow the safety instructions care-
fully.
Fill the fuel tank with the required fuel
(see technical data).
Do not use 2-speed mixture.
Check oil level of the engine.
Do not operate the appliance if the oil level
has fallen below "MIN".
If required, top up oil carefully.
Install hand spray gun
Connect high pressure hose and spray
pipe to the hand spray gun.
Install the nozzle on the spray pipe in
such a way that the marking is on the
top.
Tighten covering nut firmly.
Connect the high pressure hose to the
high pressure connection point of the
machine.
Water connection
For connection values refer to technical
–
specifications
Warning
Observe regulations of water supplier.
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is con-
sidered non-drinkable.
– 3