Descargar Imprimir esta página

Promax PROLINK-4 Manual De Instrucciones página 181

Publicidad

Idiomas disponibles

Idiomas disponibles

USER'S MANUAL. PROLINK-4
On reaching the time defined in the Start acquisition time field, the instrument
will switch itself on (if it was switched off) or go to the Datalogger mode (if switched on)
to automatically take the measurements and/or produce the print-out.
3.- MULTIPLE MEASUREMENTS: INTERVAL BETWEEN MEASUREMENTS
In the case of having to take multiple measurements at different times the
Measure interval will have to be defined. This field specifies the time interval between
measurements/print-outs. To define it, from the Datalogger configuration screen,
repeatedly press key
interval field has been activated, define the hours by turning the rotary selector [4], then
press key
[31] again to go to the minutes field and define these in the same way.
Finally press key
You can make as many acquisitions as there are activated rows in the
measurement matrix (if only one row has been activated, then only one measurement
will be taken).
In the case where the Datalogger function has been programmed to take more
than one measurement in the time domain, i.e. more than one row has been activated
and the acquisition interval is greater than four minutes, then every time an acquisition
is made the instrument will reprogram the alarm for the next measurement. Then it will
switch itself on three minutes before the time defined in the Measure Interval field in
order to warm up and ensure the highest accuracy.
4.- ERASING MEASUREMENTS STORED IN THE DATALOGGER AND AUTOMATIC
DEACTIVATION OF ALL THE CELLS.
The configuration screen also allows you to erase all the measurements stored
in the Datalogger function, as well as automatically deactivating all the activated
measurement configurations. To erase the stored measurements select the Clear field
and press the rotary selector [4]. To deactivate the measurement configurations select
the Unselect field and press the rotary selector [4].
5.- EXITING THE CONFIGURATION SCREEN
To exit the Datalogger function configuration screen press the rotary
selector [4].
4.9.4.4.2
Selecting the Measurement to be Taken
Once the Datalogger function has been configured, activate the measurement
configuration(s) (columns) which you would like to use. The headings of the measurement
matrix columns of the Datalogger function coincide with the number of memorised
measurement configurations, simply place the cursor over each column and you will see
the more important parameters displayed at the bottom of the screen (name assigned to
the memory position, frequency/channel, measurement mode and units of measurement).
02/2003
[31] until the section dealing with time in the Measure
[31] again to validate the defined time interval.
Page 63

Publicidad

loading