To activate the measurement configurations repeatedly press key
until the cursor is placed on the columns field, next turn the rotary selector [4] until it is
positioned in the column (memory) that you wish to activate and press the rotary
selector [4].The activated columns are more brilliant than the non activated ones. To
deactivate a column follow the same steps as in activating it.
To activate rows where you wish to store measurements use key
place the cursor on the rows field, then turn the rotary selector [4] until it is over the row
you want to activate and press the rotary selector [4]. The activated rows are more
brilliant than the non activated ones. To deactivate a row follow the same steps as in
activating it. In the case of activating more than one row, the time interval between the
measurement of each row is determined by the Measure interval parameter defined in
the configuration screen (1 minute by default).
4.9.4.4.3
Taking Measurements
In addition to execution by alarm (see section '4.9.4.4.1 Configuring the
Datalogger Function') there are three more ways to take measurements:
a)
Acquisition over a time period.
The measurement defined in a memory (column) will be taken as many
times as there are activated rows, as specified by the time interval between
measurements defined in the configuration menu (Measure interval).
Process: place the cursor on the column you want and press the rotary
selector [4] until the first active cell blinks. If no measurement matrix row
has been previously activated, the bottom of the screen will show the error
message "NOT CELLS SEL." (No cells selected).
b)
Acquisition of different measurements at the same moment.
Multiple measurements in a row will be taken, as specified by the
measurement configurations defined in all the activated columns.
Process: place the cursor on the row you want and press the rotary
selector [4] until the active cells blink. If no measurement matrix column has
been previously activated, the bottom of the screen will show the error
message "NOT CELLS SEL.".
c)
Multiple acquisitions.
All the measurements defined by all the activated rows and columns will be
taken, in the case where more than one row has been activated the time
interval between measurements will be that defined in the Measure interval
field of the configuration menu.
Process: select the Run function and press the rotary selector [4]. If no
measurement matrix element has been previously activated, the bottom of
the screen will show the message "NOT CELLS SEL.".
Page 64
USER'S MANUAL. PROLINK-4
[31]
[31] to
02/2003