Operating Instructions SATA FDG
EN
[2‑4] / [3‑4] / [8‑6] / [9‑5] .
■ Undo the toggle screw [1‑10] / [7‑13] .
■ Open the clamp [1‑7] / [7‑11] outwards.
■ Take the tank cover [1‑5] / [7‑8] off the pressure tank [1‑8] / [7‑10].
■ Clean the pressure tank with a suitable cleaning agent (see chap-
ter 12).
■ Fill the material pressure tank with material.
Close the material pressure tank
■ Mount the tank cover [1‑5] / [7‑8] on the material pressure tank
[1‑8] / [7‑10].
■ Close the clamp [1‑7] / [7‑11] inwards and position the toggle screw
[1‑10] / [7‑13] on the inside of the cover bead.
■ Tighten the toggle screw hand-tight.
■ Connect the agitator with the power / compressed air circuit.
■ Connect the material pressure tank with the compressed air circuit and
adjust the pressure within the permitted range.
■ Connect the material and spraying air supply (see chapter 10.2).
11. Maintenance and repairs
The following chapter describes the procedures involved for maintaining
and repairing the material pressure tank.
Warning!
Fire and explosion hazard
■ Qualified personnel for maintenance and cleaning work must have an
additional qualification in explosion protection.
■ Never carry out maintenance or cleaning work in an explosive atmos-
phere.
■ Before carrying out any maintenance work, depressurise the entire
system and disconnect it from the air and material supply.
■ Ensure that there are no sources of ignition and/or naked lights or
flames in the vicinity. No smoking.
■ Check the ground connection.
48