5 Installation at Site
For the electrical connection observe the wiring diagrams (ð Section 9.3, Page 120)
(ð Section 9.3.1, Page 120) and the information for planning the control system .
The pump set is supplied with a power cable. Always connect all marked cores.
Fig. 12: Fastening the power cables
Potential equalisation The pump set is not fitted with an external potential equalisation connection (risk of
corrosion).
Sanipump VX 65/80-EN
CAUTION
Motor overload
Damage to the motor!
▷ Protect the motor by a thermal time-lag overload protection device in
accordance with IEC 60947 and local regulations.
DANGER
Operating an incompletely connected pump set
Damage to the pump set!
▷ Never start up a pump set with incompletely connected cables or non-
operational monitoring devices.
DANGER
Connection of damaged electric cables
Danger of death from electric shock!
▷ Check the electric cables for any damage before connecting them.
▷ Never connect damaged electric cables.
▷ Replace damaged electric cables.
CAUTION
Flow-induced motion
Damage to the power cable!
▷ Run the power cable upwards without slack.
1. Run the power cable upwards without slack and fasten it.
2. Remove the protective caps on the power cable immediately before connecting
the cable.
3. If necessary, adjust the length of the power cable to the site requirements.
4. After shortening the cable, correctly re-affix the markings on the individual
cores at the cable end.
1
2
93 of 449