3.3 Starting Screen
When switched on, the generator performs a succession of
checks in order to guarantee the correct operation of the system
and of all the devices connected to it.
1 Logic/system type board
2 Synergic board
3 Motor board (WF)
4 Control board (RC 300)
5 Robot interface board (RI)
6 Software version
The lack of the software version shown alongside a device (---)
indicates lack of communication with it, and correct operation
is therefore not guaranteed (consult the "Diagnostics and solu-
tions" section).
At this stage the gas test is also carried out to check the proper
connection to the gas supply system (system for automation and
robotics).
Any lack of gas flow sets off a dedicated audible and visual alarm
signal (consult the "Alarms" section).
3.4 Saving Screen
The system provides the automatic saving of all the welding
parameters on the synergic board (inside the generator) and on
the control board (FP184).
Any difference between the data saved on the 2 devices is indi-
cated with the following screen:
Select the memory to be used for the future welding operations
by rotating the encoder.
1
Control board memory
Synergic board memory
2
Number of programs present in the memory selected
3
Save the operations carried out and return to
the main screen
4
Cancel the operations carried out
34
3.5 Test screen
When the side panel (coil compartment) is open, the welding
operations are inhibited.
The test screen appears on the LCD display.
1
Cooling unit test
2
Allows the selection of the welding process
MMA
ARC AIR
TIG
MIG/MAG
Pulsed MIG/MAG
3
Wire feed
4
Gas test
5
Wire speed
Allows the regulation of the wire feed rate.
Minimum 1 m/min, Maximum 22 m/min,
Default 1.0m/min
6
Side panel open
3.6 Main Screen
Allows the control of the system and of the welding process,
showing the main settings.
1
Heading
Allows the display of certain pieces of important infor-
mation relating to the selected process:
- The synergic curve selected