45
External parameter 1
Allows the management of external parameter 1 (mini-
mum value, maximum value, default value, parameter
selected).
(Consult the "External controls management" section).
46
External parameter 2
Allows the management of external parameter 2 (mini-
mum value, maximum value, default value, parameter
selected).
(Consult the "External controls management" section).
47
Lock/unlock
Allows the locking of the panel controls and the inser-
tion of a protection code (consult the "Lock/unlock"
section).
48
Buzzer tone
Permits adjustment of the buzzer tone.
Minimum Off, Maximum 10, Default 5
49
Contrast
Permits adjustment of the display contrast.
Minimum 0, Maximum 50, Default 25
99
Reset
Allows the resetting of all parameters to the default
values.
Allows the resetting of the whole graphic interface
according to the manufacturer's settings.
List of set up parameters (MIG/MAG)
0
Save and quit
Allows you to save the changes and exit the set up.
1
Reset
Allows you to reset all the parameters to the default
values.
2
Synergy
Allows selection of the manual MIG
(
) or synergic MIG (
the type of material to be welded.
(Consult the "Synergic curves screen" section).
3
Wire speed
Allows the regulation of the wire feed rate.
Minimum 1 m/min, Maximum 22 m/min, Default 1.0m/min
4
Current
Allows the regulation of the welding current.
Minimum 6A, Maximum Imax
5
Part thickness
Allows the thickness of the part being welded to be set.
Allows the setting of the system via the regulation of the
part being welded.
6
Voltage
Allows the regulation of the arc voltage.
Allows regulation of the arc length during welding.
High voltage = long arc
Low voltage = short arc
Minimum 5V, Maximum 55.5V
Minimum -9.9V, Maximum +9.9V, Default syn
7
Minimum current
Allows regulation of the struck arc maintenance cur-
rent.
Allows a more or less "soft" arc to be obtained.
Low minimum current = "fierce" and "reactive" arc.
High minimum current = "gentle and soft" arc.
Minimum 12A, Maximum 250A
Minimum -50A, Maximum +50A, Default syn
8
9
10
11
12
13
) process by setting
14
15
16
17
18
Inductance
Allows electronic regulation of the series inductance of
the welding circuit.
Makes it possible to obtain a quicker or slower arc to
compensate for the welder's movements and for the
natural welding instability.
Low inductance = reactive arc (more spatter).
High inductance = less reactive arc (less spatter).
Minimum 12%, Maximum 100%, Default syn
Double pulsed
Allows enablement of the "Double Pulsed" function.
Allows regulation of the pulsation amplitude.
Minimum 0%, Maximum 100%, Default off
Pulsation time
Allows regulation of the cycle, i.e. of the impulse rep-
etition cycle.
Allows the impulse frequency to be regulated.
Minimum 0.1s, Maximum 10.0s, Default 0.5s
Secondary voltage
Allows regulation of the secondary pulsation level voltage.
Makes it possible to obtain greater arc stability during the
various pulsation phases.
Minimum -5V, Maximum +5V, Default 0V
Burn back
Permits adjustment of the wire burn time, preventing
sticking at the end of welding.
Permits adjustment of the length.
Permits adjustment of the length of the piece of wire
outside the torch.
Minimum 0.01 sec., Maximum 2 sec., Default 0.08 sec.
Soft start
Permits adjustment of the wire feed speed in the phases
prior to arc striking.
Given as a % of the wire speed set.
Permits striking at reduced speed, therefore softer and
with less spatter.
Minimum 10%, Maximum 100%, Default 50%
Pre-gas
Allows you to set and adjust the gas flow prior to striking
of the arc.
Permits filling of the torch with gas and preparation of
the environment for welding.
Minimum off, Maximum 25 sec., Default 0.1 sec.
Post-gas
Permits setting and adjustment of the gas flow at the
end of welding.
Minimum off, Maximum 10 sec., Default 2 sec.
Initial increment
Allows regulation of the wire speed value during the first
"crater-filler" welding phase.
Makes it possible to increase the energy supplied to the
part during the phase when the material (still cold) requires
more heat in order to melt evenly.
Minimum 20%, Maximum 200%, Default 120%
Crater filler
Allows regulation of the wire speed value during the weld
closing phase.
Makes it possible to reduce the energy supplied to the part
during the phase when the material is already very hot,
thus reducing the risk of unwanted deformations.
Minimum 20%, Maximum 200%, Default 120%
Spot welding
Allows you to enable the "spot welding" process and
establish the welding time.
Minimum 0.1s, Maximum 25s, Default off
37