TABELLA "B" MENU LOGICHE (logic)
LOGIC
DEFINITION
TCA
Automatic closing time
Panic opening (battery)
antipanic
(LOGIC 83)*
ra blow
Hammer during opening
c. o p
Inv. dir.
Open in other direction
Confi guration of safety input
SAFE 1.
SAFE 1
(Fig. S1, S2, S3, S4)
(Fig. T1, T2, T3, T4)
(Par. 15.1 "Reaction to commands")
Confi guration of safety input
SAFE 2.
SAFE 2
(Fig. S1, S2, S3, S4)
(Fig. T1, T2, T3, T4)
(Par. 15.1 "Reaction to commands")
Confi guration of safety input
SAFE 3.
(Fig. S1, S2, S3, S4)
SAFE 3
(Fig. T1, T2, T3, T4)
(Par. 15.1 "Reaction to commands")
Confi guration of safety input
SAFE 4.
(Fig. S1, S2, S3, S4)
SAFE 4
(Fig. T1, T2, T3, T4)
(Par. 15.1 "Reaction to commands")
ultifunc.
Multifunction input
input
operating mode
door
Door state output
operating mode.
status
type of
Locking device
operating mode
loc
fixed code
Fixed Code
INSTALLATION MANUAL
Cross out
using
DEFAULT
setting
1
1
Automatic Closing ON/OFF (TCA and Clear Time)
0
1
0
Panic Feature ON/OFF (Section ANTI-PANIC FUNCTION)
0
1
0
Hammer ON/OFF during opening
0
1
Change this parameter if the opening direction needs to be changed. Fig. AK
0
0
Standard operating mode. Fig. AK
Input confi gured as active safety during opening.
0
Input confi gured as active safety during opening and check that the operation is
1
correct at the start of every procedure.
2
Input confi gured as active safety during closing.
0
Input confi gured as active safety during closing and check that the operation is
3
correct at the start of every procedure.
4
Input confi gured as active safety during opening with "detection zone".
Input confi gured as active safety during opening with "detection zone" and check
5
that the operation is correct at the start of every procedure.
Input confi gured as active safety during opening.
0
Input confi gured as active safety during opening and check that the operation is
1
correct at the start of every procedure.
Input confi gured as active safety during closing.
2
2
Input confi gured as active safety during closing and check that the operation is
3
correct at the start of every procedure.
4
Input confi gured as active safety during opening with "detection zone".
Input confi gured as active safety during opening with "detection zone" and check
5
that the operation is correct at the start of every procedure.
Input confi gured as active safety during opening.
0
Input confi gured as active safety during opening and check that the operation is
1
correct at the start of every procedure.
2
Input confi gured as active safety during closing.
0
Input confi gured as active safety during closing and check that the operation is
3
correct at the start of every procedure.
Input confi gured as active safety during opening with "detection zone".
4
Input confi gured as active safety during opening with "detection zone" and check
5
that the operation is correct at the start of every procedure.
Input confi gured as active safety during opening.
0
Input confi gured as active safety during opening and check that the operation is
1
correct at the start of every procedure.
2
Input confi gured as active safety during closing.
2
Input confi gured as active safety during closing and check that the operation is
3
correct at the start of every procedure.
4
Input confi gured as active safety during opening with "detection zone".
Input confi gured as active safety during opening with "detection zone" and check
5
that the operation is correct at the start of every procedure.
0
1
Multifunction type []- Set the multifunction input operating mode.
0
2
(Par. MULTIFUNCTION INPUT OPERATING MODE)
3
4
0
Door state output mode []. Sets the DOOR STATE output's operating mode
0
(Sect. DOOR STATUS OUTPUT OPERATION MODE)
1
0
1
2
3
4
Lock mode []. Sets the locking device's operating mode
1
(Sect. LOCKING DEVICE OPERATION MODE)
5
6
7
8
9
1
ON:
Receiver is confi gured for operation in fi xed-code mode.
0
OFF: Receiver is confi gured for operation in rolling-code mode.
0
DESCRIPTION
VISTA SL A200 SMART