Descargar Imprimir esta página

Dräger Polytron 8000 Serie Instrucciones De Uso página 44

Ocultar thumbs Ver también para Polytron 8000 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

en
|
Accessories and spare parts
16.6 Environmental parameters
Further sensor specifications and influences can be found in
the instructions for use provided for the respective sensor.
The values for accessories and spare parts may deviate from
the values given here. The exact values can be found in the
corresponding manual.
Polytron 8xx0
Values in accordance with explosion protection testing
During operation:
Pressure
Humidity
Temperatures
Polytron 8100 EC
Polytron 8200 CAT
Polytron 8310 IR
Polytron 87x0 IR
Values according to performance approval
During operation:
Pressure
Humidity
Temperatures
2)
Polytron 8100 EC
Polytron 8200 CAT
Polytron 8310 IR
Polytron 87x0 IR
During storage:
Pressure
Humidity
Temperature
Recommended storage
period
Values for relay option and installations with UL
approval
During operation:
Temperatures
Polytron 8200 CAT
Polytron 87x0 IR
1) Polytron 8200 CAT: 23.6 to 35.44 in. Hg (800 to 1200 hPa)
2) See 18.3, 18.3.2 and the instructions for use provided for the EC sen-
sor for the constraints of the maximum specification.
44
23.6 to 32.5 in. Hg (800 to
1100 hPa)
0 to 100 % RH, non-condensing
-40 to +70 °C (-40 to +158 °F)
-40 to +80 °C (-40 to +176 °F)
-40 to +65 °C (-40 to +149 °F)
-40 to +80 °C (-40 to +176 °F)
20.7 to 38.4 in. Hg (700 to
1)
1300 hPa)
0 to 95 % RH, non-condensing
-40 to +65 °C (-40 to +149 °F)
-40 to +80 °C (-40 to +176 °F)
-40 to +65 °C (-40 to +149 °F)
-40 to +77 °C (-40 to +170 °F)
26.5 to 32.4 in. Hg (900 to
1100 hPa)
0 to 100 % RH, non-condensing
-20 to +65 °C (-4 to +149 °F)
5 years
-40 to +70 °C (-40 to +158 °F)
-40 to +70 °C (-40 to +158 °F)
16.7 Tightening torques
Instrument threads
Enclosure cover
Sensor
Blind plugs
Ports (for conduits or
cable glands)
Docking Station blind
plugs
Docking Station
cable glands
Remote EC sensing
head
Field wiring terminals
Power supply, sig-
nals and relays
Grounding screw
17
Accessories and spare parts
This chapter provides an overview of the components that are
covered by the BVS 13 ATEX G 001 X- and PFG 14 G 001 X-
type examination. Further parts are listed in the spare parts
list or can be requested from DrägerService.
®
17.1 Polytron
8xx0
Description
IRDA to PC interface
Magnetic wand with key
chain
Dräger PolySoft, configura-
tion software
EXd blind plug, stainless
steel, 2 pcs.
Exd blind plug, galvanic steel,
3 pcs.
17.1.1 Docking station
Description
Docking Station Power Only
Version
Docking Station Power, Relay
(includes 2 cable glands)
Docking Station Fieldbus
Cable Gland Docking Station 6812868
Blind plug Docking Station
Instructions for use
≥44 in-lbs / ≥5 Nm
min. 266 in-lbs / min. 30 Nm
min. 266 in-lbs / min. 30 Nm
min. 443 in-lbs / min. 50 Nm
62 in-lbs / 7 Nm
70 in-lbs / 8 Nm
177 in-lbs ±9 in-lbs / 20 Nm
±1 Nm
4.4 - 7.0 in-lbs / 0.5 - 0.8 Nm
10.6 in-lbs / 1.2 Nm
Part number
4544197
4544101
8328600 / 8328639
4544897
8344041
Part number
8344027
8344028
8344029
8344042
®
|
Dräger Polytron