Quick Access and Configuration Menu
for U0 User Interface
Users have access to the two menu levels:
Quick Access – basic menu which is connected with
setting the Welding Parameters.
Configuration Menu – advanced menu, configures
the device setting.
WARNING
The Menu cannot be accessed if the system is
welding, or if there is a fault (status LED is not solid
green).
The availability parameters in the Quick Access and
Configuration Menu depend on the selected welding
program / welding process.
After the device has been restarted the user settings are
restored.
Table 3. The default settings of Quick Access
Parameter
English
Parameter Selection Mode – the Parameter Name on
the Left Display blinking.
Parameter Change Value Mode – the parameter value
on the Right Display blinking.
Quick Access
To set the parameter of Quick Access (Table 3):
Press the Right Button [25] to select mode.
Turn the Right Knob [24] to set the value of
parameter.
Press the Left Button [26] to retutn to main menu.
If user do not press Left button, system return
automatically to the main menu after few seconds.
Inductance – controls the arc characteristics when
short-arc welding. increasing Inductance greater than
0.0 results in a crisper arc (more spatter) while
decreasing the Inductance to less than 0.0 provides a
softer arc (less spatter).
Adjust range: from -10 to +10.
Factory default, Pinch is OFF.
The 2-Step - 4-Step changes the function of the
gun's trigger.
2 Step trigger operation turns welding on and off
in direct response to the trigger. Welding process
is performed when the gun's trigger is pulled.
4-Step mode allows to continue welding, when
the gun's trigger is released. To stop welding, the
gun's trigger is pulled again. 4-step mode
facilitates to making long welds.
Note: 4-Step does not work during Spot Welding.
Run-in WFS – sets the wire feed speed from the time
the trigger is pulled until an arc is established.
Factory default, Run-in is turned off.
Adjust range: from minimum to 3,81 m/min (150
in/min ).
Burnback Time – is the amount of time that the weld
output continues after the wire stops feeding. It
prevents the wire from sticking in the puddle and
prepares the end of the wire for the next arc start.
Factory default, Burnback Time is set at AUTO.
Adjust range: from 0 (OFF) to 0,25 seconds.
12