Hot Start – value in percentage of nominal value welding
current during arc start current. The control is used to set the
level of the increased current and arc start current is made
easy.
Adjust range: from 0 to +10.
Arc Force – the output current is temporarily increased to
clear short circuit connections between the electrode and the
workpiece.
Lower values will provide less short circuit current and a softer
arc. Higher settings will provide a higher short circuit current, a
more forceful arc and possibly more spatter.
Adjust range: from -10 to +10.
Restore to Factory Settings – it allows to restore the factory
settings.
View Software version – used for viewing the software
version for user interface.
First view show effects after getting access to choose the
parameter.