To remove the selected parameter or function from the
Welding Parameters Bar [44]:
Access to the User Setup.
Use the Right Knob [36] to highlight the parameter or
function icon which is added to the Welding
Parameters Bar [44].
Figure 17.
Press the Right Knob [36] – The selected icon will
disappear from the display bottom.
Figure 18.
The
Selected
parameters
disappeared from the Welding Parameters Bar [44]
Figure 19.
English
or
function
was
20
Preflow Time
shielding gas flows after the trigger is
pulled and prior to feeding.
Adjust range: from 0 seconds (OFF) to 25 seconds
(factory default is set at Auto mode).
Postflow Time
shielding gas flows after the welding output
turns off.
Adjust range: from 0 seconds (OFF) to 25 seconds
(factory default is set at Auto mode).
Burnback Time is the amount of time that
the weld output continues after the wire
stops feeding. It prevents the wire from
sticking in the puddle and prepares the end of the wire
for the next arc start.
Adjust range: from OFF to 0.25 seconds (factory
default is set at Auto mode).
Spot Timer– adjusts the time welding will
continue even if the trigger is still pulled.
This option has no effect in 4-Step Trigger
Mode.
Adjust range: from 0 second (OFF) to 120 seconds
(factory default is OFF).
WARNING
Spot Timer has no effect in 4-Step Trigger Mode.
Run-in WFS – sets the wire feed speed
from the time the trigger is pulled until an arc
is established.
Adjust range: from minimum to maximum WFS
(factory default is set at Auto mode).
The Start Procedure
and Volts (or Trim) for a specified time at the
beginning of the weld. During the start time,
the machine will ramp up or down from the
Start Procedure to the preset Welding Procedure.
Adjust time range: from 0 seconds (OFF) to
10 seconds.
Crater Procedure – controls the WFS (or
value in ampere units) and Volts (or Trim) for
a specified time at the end of the weld after
the trigger is released. During the Crater time, the
machine will ramp up or down from the Weld Procedure
to the Crater Procedure.
Adjust time range: from 0 seconds (OFF) to
10 seconds.
A/B procedure – enables quick weld
procedure change. The sequence changes
may occur between:
Two different welding programs.
Different settings for the same program.
adjusts the time that
adjusts the time that
controls the WFS
English