(7)
(8)
(9)
(10)
(11)
(12)
44
Hold indicator
Depending on the setting, the welding data is saved each time welding
ends; "Hold" appears on the display.
A indicator
Current in A
Before the start of welding, a set value is automatically displayed. The ac-
tual value is displayed during welding.
V indicator
Voltage in V
The actual value is displayed during welding.
Wire threading button
To thread the wire electrode or the welding wire into the torch hosepack
with no accompanying flow of gas or current.
Right adjusting dial with turn/press function
To select, change and set parameters.
Turn the adjusting dial: Change values, select parameters.
Press the adjusting dial: Confirm a menu selection, apply values.
A fixed parameter is stored for each process:
-
TIG DC process = Pulse frequency
-
TIG AC- process = AC- frequency
-
TIG ColdWire = Wire speed
-
TIG DynamicWire = Wire speed correction
EasyJob button
For saving, selecting, and deleting EasyJobs.
The LED on the corresponding button lights up when an EasyJob is selec-
ted.
How it works:
-
Press and hold the button for 3 seconds = save EasyJob (all current
settings are saved). After saving, the LED in the button lights up and
"Store" is shown on the display
-
Press and hold the button for 5 seconds = delete EasyJob. "Store" is
shown on the display after 3 seconds, "Clear" is shown after 5 seconds
and the LED in the button goes out.
-
Press the button = select the saved EasyJob
F1 key
For selecting a special parameter - currently not assigned!
Welding process button
The corresponding LED lights up when a welding process is selected. The
following welding processes can be selected by pressing the button: