John Bean B600 Manual De Operador página 118

Ocultar thumbs Ver también para B600:
Tabla de contenido

Publicidad

A
118
7-3
User Code
Ounces:
Grams:
Range 3.50 to 20.0 g
Range 0.25 to 2.00 oz
Factory-adjusted to 0.25 oz
Factory-adjusted to 5.0* g
Read out limit, e. g. 0.25 oz
Select another limit, e. g.: 5.50 g
Select another limit, e. g. 0.50 oz
• Select Code C8
• Set the value 5.50
After the confirmation OK, this operating mode can be
• Press ENTER
acquired in the permanent memory (C10).
Code C10
Storing the selected mode of operation in the
permanent memory
If the mode stored in the permanent memory is to be
changed, enter the desired state (e. g. on or off) for
the mode in question and transfer it via code C10 into
the permanent memory (not possible for code C4).
0* =
No storage
1 =
Data are stored in the permanent memory
To store in the permanent memory.
Press OK.
- A three-tone signal sounds to confirm acceptance.
Code C11
main shaft stop position
The positioning brake stops the main shaft close to the
correction position by initiating pulsing braking.
The positioning brake is activated after switch on and
after a measuring run has been carried out and found
an unbalance greater than the limit value.
• Select Code C11
• Select one of the following options:
0 = No positioning brake after measuring run.
1*= Positioning brake after measuring run for left plane.
2 = Position brake after measuring run for right plane.
Note: The selection is permanently acquired.
Code C12
Readings of numbers of measuring runs
Example: 220.219 measuring runs so far performed
(Fig. 7-3).
The following counters can be displayed:
1 = Total number of measuring runs
* = Factory adjusted mode