Compensation Run - John Bean B600 Manual De Operador

Ocultar thumbs Ver también para B600:
Tabla de contenido

Publicidad

3
4
94
6-1
26
6-2
1
6-3
Maintenance
6.0 Maintenance
This unit is designed to operate for a long time.
If the operator shuts down correctly (
end of each shift, no further maintenance is required.
This unit must not be opened by the operator, except
in accordance with explicit instructions.
6.1

Compensation Run

All clamping and centering means are balanced in our
works to within a certain tolerance.
To compensate for any residual unbalance that might
be left in the clamping means, it is recommended
that an electrical compensation run be performed
after switching on the machine or after changing the
wheel adaptor, especially a motorcycle wheel adaptor.
This mode cannot be transferred into the permanent
memory.
Application:
 Fit the clamping device properly on the balancer
shaft. Do not fit the wheel.
 From the MAIN MENU press key 3 (Fig. 6-1) three
times and select code C 4 COMPENSATION.
The C4 screen (Figure 6-2) will open.
 Start the Compensation Run using the START
key 4.
The Compensation Run takes longer than a regular
measuring run. After the Compensation Run, an icon
in the status Bar indicates the Compensation Active
status (1, Fig. 6-3).
Compensation remains active until cancelled by one
of the following cases:
- Selection of state 0 in code C 4 and confirmation
with key 26,
- by starting readjustment
- or an optimization run,
- or by switching off the machine.
5.2.4) at the

Publicidad

Tabla de contenido
loading

Tabla de contenido