John Bean B600 Manual De Operador página 46

Ocultar thumbs Ver también para B600:
Tabla de contenido

Publicidad

3
X
46
2
1
1
5-5
Operation
5.4
Dimensional detections
The dimensions of the balance weights are detected,
on the basis of real data, or rather on measurements
taken directly by the Gauges if the automatic Easy
Alu function is used (
5.5) these figures are calculated on the
manually (
basis of nominal values by adding or subtracting the
average correction values.
5.4.1
Parameter Gauge
The internal Parameter Gauge for distance and
diameter is used to enter the distance between the
machine and the left correction plane, as well as the
nominal rim diameter/correction diameter.
The internal Parameter Gauge allows the effective
correction planes and diameters of the adhesive
weights fixed to the bead seats and hidden weights to
be calculated exactly.
Fig. 5-5 Internal Parameter Gauge for rim distance
and diameter.
1 Internal Parameter Arm gauge head
2 Gauge head
3 Reference edge for distance reading X
– Using the distance and diameter measurement
Internal Gauge (1, Figure 5-5) the distance
between the machine and the left correction plane
is detected and obtained automatically as well as
the diameter of the rim.
Application:
 Extract and rest the Gauge Head on the rim and
keep it in position until an audible signal is heard.
 Move the Gauge to the idle position.
When the measurements have been completed and
the idle position is reached, the rim dimensions are
shown on the screen in the indicator fields between
the relative arrows. A selection of weight positions (Alu
type) is also shown.
If the Gauge doesn't function correctly or if the
correction positions on the wheel on the machine are
outside the calibration reading field, it is still possible
to set the dimensions from the menu and proceed in
manual mode (
5.5).
5.6). If the data is entered

Publicidad

Tabla de contenido
loading

Tabla de contenido