92
26
5-63
5-64
5-51
5-65
Operation
Reading of error code E9
If E9 is read out, at least one error was made with
respect to the sequence of operations when performing
Optimization (System messages
Abort the Optimization program by pressing the
STOP key and, if desired, start Optimization once
again.
Fig. 5-63 Minimization "Un.12"
Clamp the wheel on the balancer.
Rotate the wheel such that the valve is exactly
perpendicular to and above the main shaft.
Confirm the valve position by pressing menu key
26.
The Minimization "Un.13" screen (Fig. 5-64) is
displayed.
Fig. 5-64 Minimization "Un.13"
START is displayed on the screen.
Spinn the wheel.
A measuring run is performed.
The BALANCING screen (Fig. 5-51) is displayed.
Finish weight Minimization
Fig. 5-51 BALANCING
Balance the wheel according to the readings.
If the wheel quiet running conditions cannot be
improved on, the following message is displayed:
Fig. 5-65
H0 Wheel running conditions cannot be improved by
Optimization.
7.1).