Descargar Imprimir esta página

SICK WTM10L Instrucciones De Uso página 56

Barreras fotoeléctricas híbridas
Ocultar thumbs Ver también para WTM10L:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 70
OPERATING INSTRUCTIONS
en
6.4
Settings
56
O P E R A T I N G I N S T R U C T I O N S | WTM10L
Minimum object height in mm (inch)
y
30
(1.18)
20
(0.79)
6%/6%
90%/6%
10
6%/6%
(0.39)
90%/6%
1
0
0
50
150
(1.97)
(5.91)
Recommended sensing range for
the best performance
Figure 16: Characteristic curve, WTM10L-xxxxx2
1
25
220
2
25
3
25
0
50
150
250
(1.97)
(5.91)
(9.84)
C/D
A
Recommended sensing range for
the best performance
Figure 17: WTM10L-xxxxx2
Black object, 6% remission factor, Mode 1: Speed
1
Black object, 6% remission factor, Mode 2: Standard
2
Black object, 6% remission factor, Mode 3: Precision
3
A
Sensing range min. in mm
B
Sensing range max. in mm
C
Field of view
D
Adjustable switching threshold for background suppression
Blue
Recommended sensing range for the best performance
Factory configuration
The following configurations are preconfigured:
Table 11: Factory configurations
Detection mode
Operating mode
Example:
Reliable detection of the object
6%/6%
90%/6%
3 3
2
x
250
350
450
(9.84)
(13.78)
(17.72)
Distance in mm (inch)
300
400
350
450
(13.78)
(17.72)
Distance in mm (inch)
B
BGS
Standard mode
x
y
Background
Black background (6 % remission factor)
Distance of sensor to background x = 300 mm
Required minimum object height y = 10 mm
For all objects regardless of their colors
9382969/2024-02-23 | SICK
Subject to change without notice

Publicidad

loading

Este manual también es adecuado para: