When the machine is disconnected from the air supply, the devices
bearing the sign shown above may remain pressurised.
Before carrying out any maintenance operation or topping up with lubricant, disconnect
the machine from the compressed air supply line.
To increase the effectiveness of the inflation jets, always liberally lubricate beads
and raise the lower bead while activating inflation jets.
The purpose of the regulator filter unit plus lubricator (FRL) is to filter the air, adjust the
pressure and lubricate it.
The "FRL" unit supports a maximum input pressure of 18 bar and has an adjustment range
of 0.5 to 10 bar. The setting may be modified by pulling the handle out and then turn-
ing. After adjusting, return the handle to the locked position by pushing down (fig.47a).
The lubricant flow-rate is adjusted by turning the screw on part "L", (fig.47b); normally
this unit is precalibrated to a pressure of 10Bar, with SAE20 viscosity lubricant in order
to make a drop of lubricant come out, which can be seen from the specific cover, every
4 times the bead breaker is operated.
Periodically check the lubricant level through the specific windows and top up as shown
in fig.47c. Top up only with non-detergent SAE20 oil equal to 50cc.
The filter regulator "FR" has an automatic condensation drain system, therefore in condi-
tions of normal use special maintenance is not required. The condensate may however
be drained manually at any time (fig.47d).
Normally the cups do not need to be removed, but check if this is necessary for mainte-
nance operations after a long period of use. If a manual operation is not sufficient, use
the specific key provided (fig.47e).
Clean with a dry cloth. Avoid contact with solvents.
Keep the work area clean.
Never use compressed air, water jets or solvents to remove dirt or deposits from the
machine. When cleaning the area, take steps to avoid building up and raising dust as
far as possible.