1.2.c. ELECTRICAL AND PNEUMATIC CONNECTIONS
For ARTIGLIO 55 see the manual 4-133267.
The dimensions of the electric hook-up used must be suitably sized in relation to:
• the electric power absorbed by the machine, indicated on its data plate (Fig. 1);
Mod.
V
Code
A
kW
Hz
X-XXXXXXXX/XX - XX
Serial N.
Ph
bar7psi
Port.max
• the distance between the machine and the
power supply hook-up point, so that voltage
drops under full load do not exceed 4% (10%
during start-up) compared with the rated
voltage specified on the data plate.
- The operator must:
• fit a power plug on the power supply lead
in compliance with the relevant safety stan-
dards;
• connect the machine to its own electrical con-
nection - A, Fig. 2 - and fit a differential safety
circuit-breaker with 30 mA residual current;
• fit fuses to protect the power supply line, rated as indicated on the general wiring
diagram in this manual;
• connect the machine to an industrial socket; the machine must not be connected to
domestic sockets.
An effective grounding connection is essential for correct operation of the machine.
Make sure the available pressure and the rendered capacity of the compressed air
system are compatible with those required for correct machine operation - see the
"Technical Data" section. For correct machine operation, the compressed air supply
line must provide a pressure range from no less than 8.5 bar to no more than 16 bar
and guarantee an air flow rate greater than the average consumption of the machine,
which is equal to 100 Nl/min.