Regular Maintenance
!
ALWAYS ENSURE THAT THE MACHINE IS SWITCHED OFF PRIOR TO ANY
REMOVE THE KEY PRIOR TO ANY MAINTENANCE OPERATION.
Waste Water Tank Full
1
3
Located under the top tank at the front of the machine is a clean water filter. Fig5
Note: Make sure the top tank is empty before lifting.
MAINTENANCE USING THE MASTER CONTROL ON/OFF KEY.
After use, empty waste water tank
A
using emptying hose and flush out
with clean water.
Next remove floor tool vacuum hose
B
and flush out with clean water.
A
Next empty clean water tank, using
C
emptying hose and again flush out
with clean water.
Whilst pressing in the top tank hood toggles,
remove the hood. Fig1
The hood also has a sealing-rubber which
should be examined at every clean-down.
Rinse using clean water, avoiding the
vac filter.
Located in your waste water (top) tank is
a full tank switch, this stops your machine
from working once the waste water reaches
its maximum limit.
Sometimes the switch gets clogged and
blocked, clean to ensure correct operation.
Fig2
Also ensure float pad is clean and in the
correct position.
IMPORTANT
Remove vac filter and clean if required
(keep dry). Fig3
Never use the machine without the
recommended filter as it may cause
damage to the machine.
Remove debris basket filter and rinse
using clean water, and refit. Fig4
IMPORTANT If the debris basket is
allowed to become clogged, vacuum
performance can deteriorate.