Installation
These pumps connect to an internal camlock
that is part of a bulk container system
(→ fig. 4, page 15 for a typical installation)
Additional items that should be
incorporated into the air piping systems are
listed in Table 5.
Prove pump
Aerated product is due to external leakage;
either at the pump or at the connection
fittings on the bulk container Isolation of the
pump from the bulk container can help
"prove" the pump
1 Place the pump in oil
2 Follow steps 9 - 13 within the section
entitled Bench test, page 14
If the pump does not leak externally the
fittings on the bulk container may not be
sealing properly The pump may still contain
an air leak at o-rings (11 and/or 24) Refer to
the Troubleshooting, page 16 for details
Air line components
Part number
Description
5612-2
Moisture separator
SM7612-B
Regulator and gauge
5912-2
Lubricator
1)
1)
Although the air motor is lubricated at the factory, the life
of the motor can be extended with the use of a lubricator
8