3 TECHNICAL DATA
3
TECHNICAL DATA
Mains voltage
Primary current I
max
MIG/MAG
TIG
MMA
No-load power in energy-saving
mode 6.5 min. after welding
Setting range
MIG/MAG
TIG
MMA
Permissible load at MIG/MAG
60 % duty cycle
100% duty cycle
Permissible load at TIG
60 % duty cycle
100% duty cycle
Permissible load at MMA
60 % duty cycle
100% duty cycle
Power factor at maximum current
MIG/MAG
TIG
MMA
Efficiency at maximum current
MIG/MAG
TIG
MMA
Electrode types
Open-circuit voltage
without VRD function
Operating temperature
Transportation temperature
Constant sound pressure when
idling
Dimensions l × w × h
Weight
0221323
Warrior 400i CC/CV
380-460 V ±10%,
3~ 50/60 Hz
27 A
23 A
29 A
30 W
16 A/15 V - 400 A/34 V
5 A/10 V - 400 A/26 V
16 A/20 V - 400 A/36 V
400 A/34 V
300 A/29 V
400 A/26 V
300 A/22 V
400 A/36 V
300 A/32 V
0.84
0.75
0.82
91 %
88 %
91 %
Basic
Rutile
Cellulosic
71 V DC
-10 to +40°C
-20 to +55°C
<70 db (A)
712 × 325 × 470 mm
52.5 kg
- 56 -
Warrior 500i CC/CV
380-460 V ±10%,
3~ 50/60 Hz
37 A
30 A
38 A
30 W
16 A/15 V - 500 A/39 V
5 A/10 V - 500 A/30 V
16 A/20 V - 500 A/40 V
500 A/39 V
400 A/34 V
500 A/30 V
400 A/26 V
500 A/40 V
400 A/36 V
0.88
0.85
0.88
90 %
87 %
91 %
Basic
Rutile
Cellulosic
84 V DC
-10 to +40°C
-20 to +55°C
<70 db (A)
712 × 325 × 470 mm
52.5 kg
© ESAB AB 2014