The building work must be finished in such a way that the woodburner can expand during operation: the
brickwork must never be supported on or against the sides of the appliance. Leave a minimum expansion
joint of 0.5 cm on each side and at least 1 cm the top of the front.
1. Fumes exhaust pipe Ø 200 or 150, according to model.
8
2. Entry of air into the chimney chamber by natural convection.
3. Entry of air into the cassette convection chamber, drawn in by fans .
4. Optional entry of air from the outside used for combustion
(optional lower or rear connection)
7
5. Hot air outlet at the top of the front blown by fans .
6. Hot air outlet driven by fans .
6
7. Hot air outlet of the chimney chamber by natural convection. .
8. Optional outlet for hot air to other rooms, blown by fans
5
3
2