_MSK.book Seite 29 Montag, 26. Februar 2007 10:15 10
SinePower
For the electrical connection you will need the following tools:
Crimping tool
3 multi-coloured, flexible connection cables. Determine the necessary
thickness from the table in the "Connecting the inverter" chapter on
page 30.
Cable lugs and conductor sleeves
For fastening you will require the following tools:
Machine bolts (M4) with washers and self-locking nuts or
self-tapping screws or wood screws.
7.2
Installation instructions
When selecting the installation location, observe the following instructions:
The inverter can be mounted horizontally or vertically.
The inverter must be installed in a place that is protected from moisture.
The inverter may not be installed in the presence of flammable materials.
The inverter may not be installed in a dusty environment.
The place of installation must be well-ventilated. A ventilation system
must be present for installations in small, closed spaces. The minimum
clearance around the inverter must be at least 25 cm (1, page 3).
The air intake on the underside or the air outlet on the back side of the
inverter must remain clear.
For ambient temperatures higher than 40 °C (such as in engine or heating
compartments, or direct sunlight), the heat from the inverter under load
can lead to the automatic shut-off of the inverter.
The installation surface must be level and sufficiently strong.
Caution
Before drilling any holes, ensure that no electrical cables or other
parts of the vehicle can be damaged by drilling, sawing and filing.
Fitting the inverter