_MSK.book Seite 36 Montag, 26. Februar 2007 10:15 10
Cleaning and caring for the inverter
9.3
Switching to energy-saving mode
You can switch to energy-saving mode using the dip switches S1, S2 and S3
on the front. In this way, the battery you connect to the inverter is not dis-
charged as quickly.
The inverter operates in energy-saving mode as long as the required power
is below the set level. If the required power exceeds the set level, the inverter
works in normal mode.
The values to be set on your inverter can be found in the following table:
Energy-saving mode up to
MSK700-012
MSK700-024
Off
15 W
30 W
40 W
56 W
70 W
84 W
100 W
9.4
Connecting the remote control (accessory)
➤ Connect the remote control (accessory) to the "Remote Port" connection
(7 4, page 4 or 8 4, page 4).
➤ Set the main switch (6 2, page 4) to "Remote".
10
Cleaning and caring for the inverter
Caution
Do not use sharp or hard objects for cleaning as these may
damage the device.
➤ Occasionally clean the device with a damp cloth.
36
MSK1000-012
MSK2000-012
MSK1000-024
MSK2000-024
MSK1500-012
MSK3000-012
MSK1500-024
MSK3000-024
Off
Off
20 W
40 W
40 W
80 W
50 W
100 W
60 W
120 W
80 W
160 W
84 W
180 W
110 W
220 W
SinePower
Dip switch
S1
S2
S3
Off
Off
Off
On
Off
Off
Off
On
Off
On
On
Off
Off
Off
On
On
Off
On
Off
On
On
On
On
On

Publicidad