11
Rectifying faults
If you have detailed questions on the specifications of the
inverter please contact WAECO.
Warning
Do not open the rechargeable device. You risk electrocution by
doing this.
No output voltage
The "Status" LED (6 5, page 4) lights up red to indicate the fault:
LED display
Quick flashing
Slow flashing
Occasional flashing
Permanently lit
Cause
Input voltage too high
Input voltage too low
Overheating
Short circuit or reversed
polarity
Excessive load
Rectifying faults
Remedy
Check the input voltage and reduce
it.
The battery needs charging.
Check the cables and connections.
Switch off the inverter and the con-
sumer unit.
Wait 5 to 10 minutes and switch the
inverter on again without any con-
sumer units.
Reduce the load and make sure the
inverter is better ventilated. Then
switch the consumer unit back on.
Switch off the inverter and remove
the consumer unit.
Then switch the inverter back on
without the consumer unit. When no
excessive load is now shown, there is
a short circuit in the consumer unit or
the total load was higher than the
power specified in the data sheet.
Check the cables and connections.
37