Cleaning The Pump Strainer Basket - Pentair VS2 Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 82
16
DO NOT open the strainer pot if VS2 Variable Speed Pump fails to prime or if pump has been operating without water in the strainer pot.
Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump
may cause serious personal injury. In order to avoid the possibility of personal injury, make sure the suction and discharge valves are open and
strainer pot temperature is cool to touch, then open with extreme caution.
To prevent damage to the pump and for proper operation of the system, clean pump strainer and skimmer baskets regularly.
Pump Strainer Basket
The pump strainer basket (or 'strainer pot', 'hair and lint pot'),
is located in front of the volute. Inside the chamber is the
basket which must be kept clean of leaves and debris at all
times. View basket through the 'See Through Lid' to inspect
for leaves and debris.
Regardless of the length of time between filter cleaning,
it is most important to visually inspect the basket at least
once a week.

Cleaning the Pump Strainer Basket

1. Press the Start/Stop button to stop the pump and turn
off the pump at the circuit breaker.
2. Relieve pressure in the system by allowing the water to
cool.
3. Gently tap the clamp in a counter-clockwise direction to
remove the clamp and lid.
4. Remove debris and rinse out the basket. Replace the
basket if it is cracked.
5. Put the basket back into the housing. Be sure to align
the notch in the bottom of the basket with the rib in the
bottom of the volute.
6. Fill the pump pot and volute up to the inlet port with
water.
7. Clean the cover, O-ring, and sealing surface of the pump
pot. Note: It is important to keep the lid O-ring clean and
well lubricated.
8. Reinstall the lid by placing the lid on the pot. Be sure the
lid O-ring is properly placed. Seat the clamp and lid on the
pump then turn clockwise until the handles are horizontal.
9. Turn the power on at the house circuit breaker. Reset the
pool time clock to the correct time, if applicable.
10. Open the manual air relief valve on top of the filter.
11. Stand clear of the filter. Start the pump.
12. Bleed air from the filter until a steady stream of water
comes out. Close the manual air relief valve.
THIS SYSTEM OPERATES UNDER HIGH
PRESSURE. When any part of the circulating
system (e.g., Lock Ring, Pump, Filter, Valves,
etc.) is serviced, air can enter the system and
become pressurized. Pressurized air can cause
the lid to separate which can result in serious
injury, death, or property damage. To avoid this
potential hazard, follow above instructions.
MAINTENANCE
Winterizing
You are responsible for determining when freezing conditions
may occur. If freezing conditions are expected, take the
following steps to reduce the risk of freeze damage. Freeze
damage is not covered under warranty.
To prevent freeze damage, follow the procedures below:
1. Press the Start/Stop button to stop the pump and shut
off electrical power for the pump at the circuit breaker.
2. Drain the water out of the pump housing by removing
the two thumb-twist drain plugs from the housing. Store
the plugs in the pump basket.
3. Cover the motor to protect it from severe rain, snow and
ice.
Note: Do not wrap motor with plastic or other air tight
materials during winter storage. The motor may be covered
during a storm, winter storage, etc., but never when operating
or expecting operation.
Note: In mild climate areas, when temporary freezing
conditions may occur, run your filtering equipment all night
to prevent freezing.

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido