4.3. Battery
The battery equipped for this vehicle is a valve-regulated
wet-load free battery. It is strictly prohibited to pry open the
shell. The electrolyte does not need to be replenished before
and during use. If the positive and negative battery terminals
are dirty or corroded, clean the battery terminals. Do not
remove the battery sealing cover. It is not necessary to
remove the sealing cover during charging.
• If the battery sealing cover strip is removed, the
Attention
battery will be irreparably damaged.
• Improper handling of batteries is hazardous to
human health and the environment. If the battery is scrapped,
please hand it over to the designated dealer for recycling. Do not
dispose of it privately.
Read and observe the following precautions
before use:
1. Check the battery terminal voltage when it is used for the
first time. When the voltage is less than the 12.6V, it is
necessary to charge: charge voltage 14.5±0.02 V, charge
limit current 11A, charge until the current drops to 0.2A (or
refer to the relevant parameters printed on the surface of
the battery). If the temperature of the battery is higher than
45°C during charging, stop charging immediately and
charge again after the temperature drops.
2. The battery terminal red is positive and black is negative.
Turn off the power supply during wiring, connect the
positive electrode first and then the negative electrode;
Maintenance and Care
remove the negative electrode first and then the positive
electrode during disassembly.
3. Charging system test: After the vehicle is started, the
battery voltage displays between 13.5V and 14.7V, indicating
that the charging system is normal.
4. Vehicle leakage current detection: Turn off the power
supply of the vehicle, connect the positive or negative pole
in series with the multimeter (current gear), the current is
less than 3mA, and the vehicle circuit is normal.
5. If the motorcycle is not used for a long time, it should be
recharged once a month, or the battery should be removed
and placed separately, and the voltage should be detected
once every three months. When the voltage is lower than
the 12.6 V, it should be recharged. It is not allowed to store
the battery in the state of lack of electricity.
Clean the positive and negative battery terminal
1. Turn off the power switch of the motorcycle.
2. Remove the driver seat cushion.
• Open the rear passenger seat cushion.
• Take out the driver seat cushion after removing the driver
seat cushion bolts.
3. Remove the battery fixing belt.
4. Remove the negative end (-) screw first and then the
positive end (+) screw.
5. Take out the battery gently, and install the battery in the
reverse order.
47