FAULT
After having carried out the various connections and having supplied
voltage, all the LEDS are switched off.
The motor opens and closes, but it has no strength and moves slowly.
The gate opens but does not close after the time set.
The gate does not open or close by activating the various K, Radio, Open
and Close buttons.
The electric lock does not work.
LED DL1 blinks rapidly and no movement is activated.
ACCESSORIES
For the connections and the technical data of the optional equipments follow the relevant handbooks.
LONG LEVER
The long lever is suggested for a leaf with a distance up to 500 mm between the hinge
of the leaf and the internal side of the pillar.
STRONG BOX FLAT
It is a strong metal (die-cast aluminium) container with lock to protect manual release and/or
push button. It is provided with a rocker switch and unlocking device (needs cable ACG8022).
It has to be fitted onto the wall.
In die-cast aluminium - IP54
ELECTRIC LOCK
Horizontal lock - right external view - 12Vac
Horizontal lock - left external view - 12Vac
Vertical lock - 12Vac
All manuals and user guides at all-guides.com
Check fuses F1, FUSE 1.
If the fuse is blown, use only a suitable replacement.
F1 T 2A
TRANSFORMER PROTECTION FUSE (on the outside of the T2 PREMIER 24V board)
FUSE 1 8A MOTOR PROTECTION FUSE
Check trimmers RUN and LOW-SPEED adjustment.
Make sure that the TCA trimmer is activated with LED DL6 on.
OPEN button always on, replace the OPEN control button or switch.
Sensor Auto test failed, check the connections between the control panel and the sensor power supply.
Warning: If you are not using a power supply for the sensors, DIP 12 should be OFF.
Faulty safety edge contact. Faulty photocells contact with DIP 4 OFF.
Fix or replace the relative contact.
Ensure to have enabled DIP 8 at ON.
Place dip switches 1, 2 or 3 in the OFF position.
code ACG8034
code ACJ9071
BATTERY
code ACG8660
code ACG8670
code ACG8650
Battery 2,2Ah 12V
36
SOLUTION
STRONG BOX STONE
It is a strong metal (die-cast aluminium) container with lock to protect manual release and/or
push button. It is provided with a rocker switch and unlocking device (needs cable ACG8022). It
has to be embedded in the wall. In die-cast aluminium - IP54
UNLOCKING CABLE
Cable for manual releasing the operators from outside, to be connected to strong box.
BATTERY CHARGE CARD
code ACG9515
code ACJ9078
code ACG8022
code ACG4648