Control Techniques Commander SE11200025 Guia Del Usuario página 60

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

A change to this parameter is only implemented if the drive is disabled or tripped
NOTE
and the Stop/Reset key is pressed for 1 second.
The Enable and Run terminals should be open when this parameter is changed.
No.
Function
Start/Stop
35
logic select
This parameter changes the functions of terminals 9, 10 and 11, which are normally
associated with enabling, starting and stopping the drive.
A change to this parameter is only implemented if the drive is disabled or tripped
NOTE
and the Stop/Reset key is pressed for 1 second.
Parameter 35
0
1
2
3
Parameter 35 = 0
Parameter 35 = 2
No.
Function
Analog
36
output select
Fr - A voltage proportional to motor speed is produced on terminal 6
Ld - Motor Load Output
AdV - An advanced parameter has been programmed to output a signal on terminal 6.
See the Commander SE Advanced User Guide.
No.
Function
Switching
37
frequency
3 - 3kHz
6 - 6kHz
12 - 12kHz*
*12kHz is not available on Commander SE Size 5.
60
Type
Limitations
RW
U, R
Terminal 9
Terminal 10
Enable
Run Forward
Not Stop
Run Forward
Enable
Not Stop
7
+24V
9
Enable
10
Run Forward
11
Run Reverse
7
+24V
9
Enable
10
Run
11
Forward/Reverse
Figure 6.8 Connection details (Positive logic)
Type
Limitations
RW
T
---------------------------------------------------------------- -
V
=
OUT
1.5
Type
Limitations
RW
U
www.controltechniques.com
Range
Units
0 - 3
Terminal 11
Run Reverse
Run Reverse
Run
Forward/Reverse
Run
Forward/Reverse
Parameter 35 = 1
Parameter 35 = 3
Range
Units
Fr, Ld, AdV
Active current
×
Drive rated current
Range
Units
3, 6, 12
Defaults
0
0
Mode
Non Latching
Latching
Non Latching
Latching
7
+24V
9
Not Stop
10
Run Forward
11
Run Reverse
7
+24V
9
Not Stop
10
Run
11
Forward/Reverse
Defaults
Fr
Fr
×
10
Defaults
6
kHz
6
Commander SE User Guide
Issue Number 9
EUR
USA
EUR
USA
EUR
USA

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido