Resolution range:
– 3: 1280 x 960 pixels
Z
Type of protective screen:
– -: Plastic
– G: Glass
– P: Polarization filter
X
V: Stainless steel housing
F001: NPN inputs/outputs
H: Heating
Commissioning
Mounting
2
all dimensions in mm
Mount via bore holes in the housing for M4 screws or with BT 320 mounting
brackets or the BTU 320M-D12 mounting system (see the operating instructions,
Chapter "Ordering information and accessories").
NOTICE
Ä
Mount the device on a metal mounting bracket.
NOTICE
Degree of protection IP65 is achieved only if the connectors and caps
are screwed into place.
Electrical connection
CAUTION
Safety notices!
Ä
Before connecting the device, please ensure that the operating
voltage matches the value printed on the nameplate.
Ä
Ensure that the functional earth (FE) is connected correctly. Fault-
free operation is only guaranteed if the functional earth is con-
nected properly.
Ä
If faults cannot be rectified, take the device out of operation. Pro-
tect the device from accidentally being started.