DETAILS AND MEASUREMENTS OF THE DIFFERENT TYPES OF EXTERNAL
MOTOR AVAILABLE DEPENDING ON THE VERSION:
HT75EXT - V.1400 - Type 1
AW57 - V.2100 - Type 2
3. TECHNICAL SPECIFICATIONS FOR MOTOR SYSTEMS
MOTOR INTERNAL
Ducting size
Air flow Máx. (200Pa) CFM
Current Draw
Power Input
Type protection
Máx. ducting distance (recommended)
MOTOR EXTERNAL
Ducting size
Air flow Máx. (200Pa) CFM
Current Draw
Power Input
Type protection
Máx. ducting distance (recommended)
Notes:
Minimize number of curves along the ducting, since each one significantly reduces airflow capacity:
For 6" 90º equals 3'
For 8" 90º equals 8'
EN
- 12 -
HT75EXT - V.1400 - Type 2
AW57 - V.2100 - Type 3
HR05
HS13
INT - Ø5"
INT - Ø6"
182 cfm
344 cfm
1,25 A
1,98 A
142 W
235 W
IP44
IP20
19'9"
19'9"
HT75 EXT
AV57 EXT
EXT - Ø6"
EXT - Ø8"
512 cfm
838 cfm
3,30 A
2,85 A
380 W
335 W
IP20
IP44
36'
36'
HT75
INT - Ø6"
512 cfm
3,30 A
380 W
IP20
32'9"