The mains power plug must be accessible after installation, unless the installer has connected the appliance
to an accessible fixed switch which ensures total disconnection under the rules mentioned in the previous
paragraph, used solely to ensure an omnipolar cut-off of power to the appliance.
Take care not to disconnect or cut the electrical wires inside the extractor hood; if this does happen, contact
your nearest after-sales service centre. Call in qualified personnel to make the electrical connection.
The connection must be made in accordance with the stipulations of current regulations.
Before connecting the Extractor Hood, ensure that the mains voltage and that of the hood match (see
identifying plate inside the appliance).
When the descriptive label inside the hood shows the
not be earthed.
When the descriptive label inside the hood does not show the
case it must be earthed.
DO NOT REMOVE THE PROTECTIVE PLASTIC COVERING FROM THE HOOD
he cable connecting the hood and the motor in External Motor models must have a section of at least 3 x 1mm
(AWG16).
For models with external motor or motor whose roof separation between hood and motor is more than 85', use
cable type AWG12 insulated section appropriate to be in the open.
The cable connecting the hood and the motor in External Motor models must have a section of at least 3 x 1mm.
In Ceiling Motor versions the cable connecting the hood and the motor must conform to HO7RN-F class
features and have a section of 3 x 1 (for lengths up to 5 metres) or 3 x 3.4mm (for lengths of up to 25 metres).
The Extractor Hood must always be connected to a properly-earthed installation. Pando takes no
responsibility for any failure to observe this rule (except for Class II appliances marked with the
Wiring has to be done and installed by a suitable qualified engineer.
No responsibility is accepted in the event of an accident due to the lack of an earth or a faulty earth
connection. If the power cable is damaged call the official after-sales service to avoid any risks.
The appliance must be disconnected from the electrical grid during installation and maintenance work.
EN
- 10 -
VERY IMPORTANT
UNTIL INSTALLATION IS COMPLETE.
This hood must be installed using a 3A fuse
Key to electrical wiring:
Green / Yellow = Earth
White = Neutral
Brown = Live / Phase
symbol, the appliance is class II. In this case it need
symbol, the appliance is class I. In this
symbol).