9. Specifications
Process connection
Type of process connection
Material
Stem
Diameter
Material (wetted)
Insertion length l
1
Measurement principle
Type of measurement principle
Remote capillary
Length
Material (non-wetted)
Accuracy specifications
Indication accuracy
Scale range in °C [°F]
-60 ... +40 [-76 ... 104]
-40 ... +60 [-40 ... 140]
-30 ... +50 [-22 ... 122]
-20 ... +80 [-4 ... 176]
-20 ... +80 [-4 ... 176]
0 ... 60 [32 ... 140]
WIKA operating instructions expansion thermometer, model 70
G ½ B, male thread
G ¾ B, male thread
G ½, female thread
G ¾, female thread
M24 x 1.5, male thread
M18 x 1.5, male thread
½ NPT, male thread
¾ NPT, male thread
Copper alloy
Stainless steel
8 mm [0.3 in]
10 mm [0.4 in]
→ Others on request
Stainless steel
20 ... 600 mm [0.78 ... 23.62 in]
→ Others on request
Bourdon tube system
Length in accordance with customer specifications (max.
10 m)
Stainless steel
Class 2 per EN 13190
Measuring range in
°C [°F]
-50 ... +30 [-58 ... 86]
-30 ... +50 [-22 ... 122]
-20 ... +40 [-4 ... 104]
-10 ... +50 [14 ... 122]
-10 ... +70 [14 ... 158]
10 ... 50 [50 ... 122]
Error limit
Scale interval
±°C
in °C
2
1
2
1
2
1
2
1
2
1
2
1
EN