en - Installation notes
Diameter and
cross-section of
the vent ducting
Connection and
conversion instruc-
tions
Gas hose
Main connection
Gas regulator valve Remove the plastic cap at the top to adjust the jet pressure. Under
36
portant to ensure that high pressure cannot arise at the side that
is not being operated. Machines fitted with fans must not be
connected to the same vent flue as those without fans.
2.
When evacuating the exhaust gas/air mixture through the exter-
ior wall, no dangers or unreasonable nuisance may arise.
3.
With a combined line, the exhaust air vent ducts for the indi-
vidual machines must be installed horizontally in the combined
line, in a way that is favourable for the flow. The cross-section of
the vent flue must not be smaller than the cross-section of the
combined line. Combined lines must be kept as short as pos-
sible and must rise vertically up to the vent flue. A condensate
drain is required at the lowest point.
All exceptional cases, and particularly those where a combined line
is being installed, require special permission from the relevant
building regulations inspector supervisor's office.
Tumble dryer
PDR 5xx SL
Connection and conversion work must be performed by the Miele
Customer Service Department or by an authorised dealer.
The settings for tumble dryers are made at the factory in line with the
gas specifications at the rear of the appliance.
The gas appliance must be connected using a corrugated metal hose
assembly made from stainless steel in accordance with DIN 3384. Al-
ternatively, a hose that complies with DIN EN 16617 may be used
with connections in accordance with DIN 3384. When selecting the
hose, the required flow rate must be taken into account. The relevant
national regulations must also be observed.
Natural gas
Hose
the plastic cap there is a screw in a hexagon. To adjust the jet pres-
sure, this screw must be adjusted with a flat-head screwdriver.
Liquid gas
Threaded union
Reducing nipple
Exhaust gas connection
Diameter/cross-section
150 mm/176 cm²
Hose