Jet
Country of destina-
tion and category
Settings with nat-
ural gas
Settings with liquid
gas 3 P
Jet pressure adjusting screw
Jet pressure measuring stub
Country
Category
Great Bri-
II
tain (GB)
2H3P
Ireland (IE)
II
2H3P
With natural gas, if the connection pressure is less than 15 mbar
(possible pressure loss in the supply network), the gas supply com-
pany must be informed.
Dryer
Heater rating
PDR 516
18 kW
Dryer
PDR 516
en - Installation notes
Connection pressure (natural
gas)
EN 437
n
min
max
p
p
p
20 mbar
17 mbar
25 mbar
20 mbar
17 mbar
25 mbar
Jet diameter
4.0 mm
Heater rating
Jet diameter
18 kW
Connection pressure measuring stub
Connection pressure (liquid
gas)
EN 437
n
min
p
p
37 mbar
25 mbar
37 mbar
25 mbar
Jet pressure
E, H
8.0 mbar
12.5 mbar
Jet pressure
2.6 mm
18.6 mbar
max
p
45 mbar
45 mbar
LL, L
37