Notes on electrical connection
• The device is designed for fixed installation with a three-pole mains cable and
may only be connected by an authorised specialist in accordance with the wiring
diagram.
• Only a qualified electrician who complies with the relevant regulations may replace
the mains cable.
• Do not use multiple plugs, socket strips or extensions, as overloading can lead to a
fire hazard.
• If the connection is no longer accessible after installation, an all-pole disconnector
with a contact opening of at least 3 mm is required.
Basic installation instructions
• Observe the specified installation dimensions exactly.
• To achieve optimum integration into the kitchen unit, install the oven in a standard
600 mm wide cabinet so that it is flush with the front of the cabinet.
• Do not hold the stove by the stove door when installing.