WARNINGS
WARNING: This air conditioner uses the flammable refrigerant R290. The air
conditioner with R290 refrigerant may cause serious damage to the human body
or surrounding objects if handled roughly.
The space required for the installation, use, repair and storage of this air
conditioner must be in accordance with the following table:
Refrigerant
Room Area
Content
m≤152g
152<m≤185g
Do not use any methods to speed up defrosting or to clean frozen parts,
except as specifically recommended by the manufacturer.
Do not puncture or burn the air conditioner and check the refrigerant line for
damage.
The air conditioner should be stored in a room without a permanent source of
fire, such as an open flame, a burning gas appliance, a working electric heater,
etc.
Note that refrigerants can be odourless.
The air conditioner should be stored in a way that prevents mechanical
damage caused by accidents.
Maintenance or repair of air conditioners using R290 refrigerant must be
carried out after a safety check to minimise the risk of incidents.
Please read the instructions carefully before installation, use and
maintenance.
Symbol
WARNING
CAUTION
CAUTION
Refrigerant
Content
≥4 m
185<m≤250 g
2
≥9 m
250 m
2
Note
This symbol indicates that this appliance
uses a flammable refrigerant. If the refrig-
erant leaks and is exposed to an external
ignition source, there is a risk of fire.
This symbol indicates that this manual
should be read carefully.
This symbol indicates that the equipment
should be handled by service personnel
with reference to the installation manual.
Room Area
≥12 m
2
m≤304 g
≥15 m
2
2