1
Bubble method: Apply of spray a uniform layer of soap water over the
suspected leak spot and observe carefully for bubble.
2
lnstrument method: Checking for leak by pointing the probe of the leak
detector according to the instruction to the suspect points of leak.
Test operation
Preparation
Verify that all piping and connection cables are well connected.
Confirm that the values at the gas side the liquid-side are fully open.
Connect the power cord to an independent power socket.
Install batteries in remote controller.
Note:
Make sure that the ventilation is good before testing.
Method:
1.
Turn on the power and push the ON/OFF switch button of the remote
controller to start the air conditioner.
2.
Select COOL, HEAT (not available on cool-only models), SWING and other
operation modes with the remote controller and see if the operation is ok.