Cabinet Height
Hole Shape and Size
15" (38.1 cm)
A 6.2" (15.9 cm) diameter round opening
is required.
A
C
D
A.
Cutout
B.
Ø 6.2" (15.9 cm)*
C.
7.7" (19.8 cm) centerline to cabinet front
D.
Centerline of the cabinet
E.
4.1" (10.6 cm)
F.
3.2" (8.3 cm) center to cabinet front
G.
Ø (4 cm)*
1
Install the 6" (15.2 cm) vent transition to the top of the
range hood liner (if removed for shipping) using two
3.5 x 9.5 mm screws. Assemble the vent duct that you
will use over the 6" (15.2 cm) vent transition.
Venting outside through the wall
1
Measure from the bottom of the range hood liner to the
horizontal centerline of the vent opening (A).
B
A
C
D
5
Remove the vent duct from the range hood liner. Transfer
measurement A to the cabinet back wall. Measure from the
underside of the cabinet.
6
Mark the cutout as shown. Use a saber saw or keyhole saw
to cut a round opening through the back of the cabinet and
the exterior wall for the vent.
C
A
B
8
B*
G*
F
E
A
A.
Measurement A
B.
Horizontal centerline of vent
opening
C.
Range hood liner
D.
12" (30.5 cm) min. cabinet height
A.
Measurement A
B.
Centerline
C.
6.2" (15.9 cm)
round cutout
Non-vented (recirculating) installation through the soffit/
cabinet
A
G
B
D
F
I
E
H
A.
Ceiling
B.
Vent cover
C.
Soffit
D.
6" (15.2 cm) vent
E.
Range hood
1
Measure and mark the centerline of the cabinet to the soffit
above.
2
Measure from the bottom of the cabinet to the centerline
of the where the vent will come through the soffit. Mark the
location and use a saber saw or keyhole saw to cut a 5.7"
(14.6 cm) hole for the vent cover.
A
*NOTE: For 12" (30.5 cm) high cabinets a 5.7" deep x 7.9" wide
(14.6 cm x 20.3 cm) rectangular opening in the cabinet top is
required for damper transition clearance.
3
Consider the cutout chart measures to make the openings
on the cabinet.
Complete preparation
1
If not yet attached, install the 6" (15.2 cm) vent transition
the top of the range hood liner using two 3.5 x 9.5 mm screws.
2
Locate side mounting bracket 1 cm bottom to top side
and against the inside of the front cabinet face. Orient the
bracket depending on the width of your cabinet as depict-
ed in the diagrams below. Drill .1" (3 mm) pilot holes in 6
places, attach a bracket using four 4.5 x 13 mm screws to
each side of the cabinet, and tighten. Additional washers
in hardware package are supplied as spacers for cabinet
walls thinner than .5"(13 mm).
B
G
C
F
D
E
F.
Cabinet
G.
Wall
H.
12" (30.5 cm) min. cabinet
height
I.
17" (43.2 cm) min. vent cover
height
B
A. Vent cover
B. Centerline