3.2
TEMPERATURE PROBE
AND WATER PRESSURE
TRANSDUCER
Antifreeze system made up of the NTC hea-
ting sensor that activates when the water
temperature reaches 6°C. Tables 1 – 1/a
include the resistance values (Ω) that are
obtained on the valve when the temperatu-
re changes and those on the
transducer when pressure changes.
The module does not work when the hea-
ting probe (SM) is cut off.
TABLE 1 (Probe)
Temperature (°C)
Resistance (Ω)
20
12.090
30
8.313
40
5.828
50
4. 1 61
60
3.021
70
2.229
80
1.669
TABLA 1/a (Transducer)
Pressure
Resistance (Ω)
(bar)
min.
0
297
0,5
260
1
222
1,5
195
2
167
2,5
137
3
108
3,5
90
COVER
COPERTURA
J2 CONNECTOR
CONNETTORE J2
KEY
TA-TA1
VZ-VZ1
3.3
ELECTRONIC IGNITION
Flame detection ignition is controlled by two
electrodes that guarantee maximum safety
with intervention time, for accidental shut-
downs or no gas, within 1 second.
3.3. 1

Operating cycle

Rotate the selector to summer or winter
and check the green led (
power is on. The burner should ignite within
max. 10 seconds. Failed ignition consequen-
tly lighting the appliance block signal may
occur due to the following:
– Ignition electrode does not spark
Only gas is supplied to the boiler and,
after 10 sec., the block led turns on.
It may be caused by the fact that the elec-
trode is cut-off or is not secured in the
ignition transformer terminal.
– No flame detection
At ignition, the electrode continues to
spark even though the burner is on. After
max.
10 sec. it stops sparking, the burner
320
turns off and the block led turns on.
269
228
The detection electrode wire is cut-off or
200
the electrode is grounded; the electrode
173
is worn and requires replacement. The
143
electronic board is defective.
113
94
A sudden blackout immediately turned off
CR1
CR
TA
( 5 )
TA
( 6 )
HOT WATER
SONDA
PROBE
SANITARIO
SB ( 11 )
SB ( 12 )
Area room thermostat
Area valve
the burner, when power is restored, the boi-
ler will automatically start.
3.4

AIR PRESSURE

SWITCH
The pressure switch signal value is measu-
red by a specific tool connected to the posi-
tive and negative pressure fixtures.
The pressure switch is factory set to 35-
) to make sure
45 Pa.
3.5
AREA SYSTEM
ELECTRICAL
CONNECTIONS
For the "DEWY EQUIPE 60 BOX/P60
BOX" heat module use a separate electri-
cal line where the room thermostats with
relevant area valves or pumps must be
connected.
Switch or relay contacts must be connec-
ted to the electronic board connector (J2)
after removing the existent bridge (fig. 17).
CIRCUITO CON VALVOLE DI ZONA
CIRCUIT WITH AREA VALVES
L
TA
VZ
R
N
NOTA: I relé vengono impiegati solo nel caso
NOTE: Relays are only used when area valves do
le valvole di zona siano prive di micro.
not have switches.
CIRCUIT WITH AREA PUMPS
CIRCUITO CON POMPE DI ZONA
L
TA
P
R
N
R-R1
Area relay
CR-CR1
Area relay contact or valve switch
P-P1
Area pump
TA1
VZ1
R1
TA
R1
P1
Fig. 17
IT
ES
GB
79